Baseline Summary B894 (WILS to WALK) Processed: Friday, Apr 02, 2004 06:52:59AM Solution type: Iono free fixed Solution acceptability: Solution acceptable Ephemeris used: Precise Met Data: Standard Baseline slope distance: 5741.088m Elevation mask: 15 degrees Variance ratio: 15.1 Reference variance: 0.554 RMS: 0.008m Horizontal Precision 1-sigma (scaled): 0.001m Vertical Precision 1-sigma (scaled): 0.002m Start time (GPS Time): 04/03/16, 19:47:15.000 1262, 244035.000 Stop time (GPS Time): 04/03/16, 20:32:15.000 1262, 246735.000 Occupation time: 00:45:00.000 Baseline Components (Mark to Mark) From: WILS Grid Local WGS 84 Northing 711395.306m Latitude 39ø34'15.02682"N Latitude 39ø34'15.02681"N Easting 1983348.729m Longitude 122ø11'37.66492"W Longitude 122ø11'37.66492"W Elevation 44.675m Height 15.861m Height 15.861m To: WALK Grid Local WGS 84 Northing 706211.795m Latitude 39ø31'27.10164"N Latitude 39ø31'27.10164"N Easting 1985816.049m Longitude 122ø09'53.89367"W Longitude 122ø09'53.89367"W Elevation 39.307m Height 10.462m Height 10.462m Baseline: ? Northing -5183.510m NS Fwd Azimuth 154ø25'25" ? X 343.131m ? Easting 2467.320m Ell. Distance 5741.073m ? Y -4106.981m ? Elevation -5.368m ? Height -5.399m ? Z -3996.881m Standard Errors Baseline Errors: ??? Northing 0.001m ? NS Fwd Azimuth 0.025 seconds ??? X 0.001m ??? Easting 0.001m ? Ell.Distance 0.001m ??? Y 0.002m ??? Elevation 0.002m ??? Height 0.002m ??? Z 0.001m Aposteriori Covariance Matrix X Y Z X 1.170e-6m2 Y 1.302e-6m2 4.465e-6m2 Z -1.049e-6m2 -1.554e-6m2 1.944e-6m2 Occupations From To Point Name: WILS WALK Data file: WILS0763-3.DAT WALK0763-3.DAT Receiver Type: 4000SSi 4700 Receiver Serial Number: 14632 220203616 Antenna type: Compact L1/L2 w/Ground Plane Compact L1/L2 w/Ground Plane Measured To: Antenna Phase Center Bottom of antenna mount Antenna height Measured 1.952m 2.000m APC 1.952m 2.063m Tracking Summary Residuals Processing Style - Precise Ephemeris Elevation Mask 15 degrees Ephemeris Precise Solution Type Fixed Static Minimum baseline observation time 120 seconds Maximum baseline length to attempt a fixed solution : Using broadcast ephemeris 200 kilometers Using precise ephemeris 2000 kilometers Kinematic Minimum reference observation time 600 seconds Minimum static initialization observation time 120 seconds Minimum known point initialization ratio 3.000 Minimum OTF processing time 200 seconds Global Frequency type L1 Maximum fixable cycle slip (static processing only) 600 seconds Maximum iterations (static processing only) 10 Maximum integer search time (static processing only) 30 minutes Antenna Model NGS Quality Single frequency Dual frequency Flag Fail Flag Fail RMS acceptance criteria 0.030 0.040 0.020 0.030 Ratio acceptance criteria 3.000 1.500 3.000 1.500 Reference variance acceptance criteria 10.000 20.000 5.000 10.000 Edit multiplier 3.500 Tropo Model Hopfield Minimum zenith delay interval 2 hours Use observed met data Enabled Iono Ambiguity resolution pass (static processing only) Enabled Apply to all baselines longer than 10 kilometers Final pass Enabled Apply to all baselines longer than 5 kilometers Events Interpolation method Linear Number of points to fit 2 Maximum allowed missing epochs 0 Time offset 0 microseconds OTF Search Search method Optimal